Numerical converter: nc01 – nc32 – Rockwell Automation 1760-DNET Pico DeviceNet Communications Module User Manual User Manual
Page 133

Publication 1760-UM003A-EN-P - September 2005
Pico GFX Control Commands 7-53
Numerical converter: NC01 – NC32
0
1
Type
0F
0F
1
2
Instance
01 – 20
01 – 20
2
3
Index
Bit IO
00
00
Mode
01
01
3 – 6
4 – 7
Data 1 – 4
00
depending on index,
Table 6.169, 6.170
Table 6.169 Index 0 – Bit IO
Bit
7
6
5
4
3
2
1
0
FB input Data 1
–
–
–
–
–
–
–
T
(1)
(1) Trigger coil. The appropriate Reset is executed if the coil is triggered (with a rising edge).
FB output Data 3
–
–
–
–
–
–
–
Q1
(2)
(2) Status 1 if the trigger coil MR..T is 1.
Table 6.170 Index 1 - Mode
Data 1
(hex)
00
Q
Outputs Q.., *Q.., S.., *S.., *SN.., QA01 are reset to 0. *
depending on the NET-ID
01
m
The marker range MD01 to MD48 is reset to 0.
02
ALL
Has an effect on Q and M.
Table 6.171 Telegram Structure
Byte
Meaning
Value (hex), sent by
Master
Slave
Master
Slave
Attribute ID
Read
92
–
Write
B2
–
Table 6.168 Telegram Structure
Byte
Meaning
Value (hex), sent by
Master Slave
Master
Slave