Local P buttons: P1 – P4
The local P buttons are the display cursor buttons of the Pico GFX
basic unit. You can scan the buttons in both RUN and STOP mode.
Only one byte has to be transferred for the P buttons.
TIP
Ensure that the P buttons are also activated via the
SYSTEM menu (in the basic unit).
Table 6.89
Byte
Meaning
Value (hex), sent by
Master
Slave
Master
Slave
Attribute ID: Read
91
–
0
Response:
Read successful
–
C2
Command rejected
–
C0
0
1
Len
02
02
1
2
Type
06
06
2
3
Index
00
00
3
4
Data 1 (Low Byte)
00
4 – 6
5 – 7
Data 2 – 4
00
00
Table 6.90 Byte 4: Data
Data 1
Bit
7
6
5
4
3
2
1
0
P1
0/1
P2
0/1
P3
0/1
P4
0/1
–
0
–
0
–
0
–
0