Synchronize clock function block: sc01 – Rockwell Automation 1760-DNET Pico DeviceNet Communications Module User Manual User Manual

Page 139

Advertising
background image

Publication 1760-UM003A-EN-P - September 2005

Pico GFX Control Commands 7-59

Synchronize clock function block: SC01

Table 6.183 Index 0 – Bit IO

Bit

7

6

5

4

3

2

1

0

FB input Data 1

EN

(1)

(1) Activates the function block on status 1.

FB output Data 3

E1

(2)

(2) Status 1 if below the minimum on duration or minimum off duration

Table 6.184 Telegram Structure

Byte

Meaning

Value (hex), sent by

Master

Slave

Master

Slave

Attribute ID: Read

92

0

Response:

Read successful

C2

Command rejected

C0

0

1

Type

20

20

1

2

Instance

01

01

2

3

Index

Table 6.185

Table 6.185

3 – 6

4 – 7

Data 1 – 4

00

depending on
index,Table 6.186

Table 6.185 Operand overview

Index
(hex)

Operand

read

write

00

Bit IO, Table 6.186

x

01

Mode/Parameter

Table 6.186 Index 0 – Bit IO

Bit

7

6

5

4

3

2

1

0

FB input Data 1

T

(1)

FB output Data 3

Q1

(2)