Transvenous pacemaker testing, Chapter 4 – Fluke Biomedical SigmaPace 1000 User Manual

Page 87

Advertising
background image

4-1

Chapter 4

Transvenous Pacemaker Testing

Contents

Page

Test Options................................................................................. 4-3

Output....................................................................................... 4-4

Demand Mode .......................................................................... 4-4

Asynchronous Mode................................................................. 4-4

Amplitude Sensitivity............................................................... 4-5

Line Frequency / Noise Immunity............................................ 4-5

Refractory Period ..................................................................... 4-5

Paced Refractory Period (PRP)............................................. 4-5

Sensed Refractory Period (SRP)........................................... 4-5

Interactive Pacemaker/ ECG Simulation .................................. 4-6

Simulated ECG Rate ................................................................ 4-6

PR Interval................................................................................ 4-6

Adjustable Threshold Level ..................................................... 4-6

Operational Modes ................................................................... 4-6

Continuous............................................................................ 4-6

Non-Capture ......................................................................... 4-7

Non-Function........................................................................ 4-7

DC Leakage.............................................................................. 4-7

Static Tests (Pacemaker Power OFF): .................................. 4-8

Dynamic Tests (Pacemaker Power ON): .............................. 4-9

Current Drain Test.................................................................... 4-9

Long Term Test ........................................................................ 4-11

Setup and Testing......................................................................... 4-11

Output....................................................................................... 4-13

Demand Mode and Dual-channel (AV) ECG Signal................ 4-16

Continuous Mode and Dual-channel (AV) ECG Signal........... 4-18

Demand Mode Pacemaker’s Ability to Sense ECG Activity ... 4-20

Amplitude of ECG Signal for a Demand Mode Pacemaker ..... 4-23

Pacemaker’s Ability to Filter Line Noise ................................. 4-28

DC Leak Test........................................................................ 4-31

DC Load Test........................................................................ 4-34

ECG Simulation Test ............................................................ 4-36

Long Term Tests ...................................................................... 4-38