Communications Time Out
This message will be displayed if the specified amount of time allowed for a response from the host
computer expires. This amount of time can be configured in the Link setup screen. This may be due
to a fault with the cable connection, cable configuration or the host computer’s communications port.

Checksum Error
The Checksum Error message will be displayed at the control if after a part has been uploaded or
downloaded, the checksum calculated by the host and the control do not match. The Checksum
calculation is performed by adding the numeric values of the ASCII codes used. This error may be
due to incorrect cabling or transmitting at too high a speed for the communications system selected.

Warning: The Master Folder Selected does Not Contain any Folders
This error message will be displayed at the host computer if the selected master folder does not
contain any subfolders. You may choose to add subfolders if they do not exist. If subfolders do exist,
the path to the master folder may be incorrect.


For additional assistance in trouble shooting the Phoenix Link in the event of a failure, please contact
our control vendor or representative.