Hypertherm HTA Rev 6.00 Install Guide User Manual

Page 221

Advertising
background image

Appendix H: Sensor™ THC

209

Sensor™ THC Part Program Support
Sensor™ THC offers the ability to configure THC setup parameters through part program codes.

The following parameters are available for use using EIA-274D G59 codes:

Arc Voltage
Pierce / Start Time
Pierce/ Start Height Factor
Cut / Mark Height


Setup is obtained using the following format.

Example:

G59 V601 Fvalue


Misc. G Code

Variable Identity

V600 = Plasma 1 Arc Voltage
V601 = Plasma 1 Pierce Time
V602 = Plasma 1 Pierce Height Factor
V603 = Plasma 1 Cut Height

V625 = Plasma 2 Arc Voltage
V626 = Plasma 2 Pierce Time
V627 = Plasma 2 Pierce Height Factor
V628 = Plasma 2 Cut Height

V650 = Marker 1 Arc Voltage
V651 = Marker 1 Start Time
V652 = Marker 1 Start Height Factor
V653 = Marker 1 Mark Height

V675 = Marker 2 Arc Voltage
V676 = Marker 2 Start Time
V677 = Marker 2 Start Height Factor
V678 = Marker 2 Mark Height


Variable Value
The selected value for the variable

Advertising
This manual is related to the following products: