Hypertherm HTA Rev 6.00 Install Guide User Manual

Page 157

Advertising
background image

Appendix C: Program Codes

145

ESSI CODE

DESCRIPTION

MAPPED TO EIA

245

Output

1

On

O1

S1

246

Output

1

Off

O1

S0

247

Output

2

On

O2

S1

248

Output

2

Off

O2

S0

249

Output

3

On

O3

S1

250

Output

3

Off

O3

S0

251

Output

4

On

O4

S1

252

Output

4

Off

O4

S0

253

Wait for Input 1 On

W1 S1

254

Wait for Input 1 Off

W1 S0

255

Wait for Input 2 On

W2 S1

256

Wait for Input 2 Off

W2 S0

257

Wait for Input 3 On

W3 S1

258

Wait for Input 3 Off

W3 S0

259

Wait for Input 4 On

W4 S1

260

Wait for Input 4 Off

W4 S0

282

Marker

Offset

3

On

M275

283

Marker

Offset

3

Off

M274

284

Marker

Offset

4

On

M277

285

Marker

Offset

4

Off

M276

286

Marker

Offset

5

On

M279

287

Marker

Offset

5

Off

M278

288

Marker

Offset

6

On

M281

289

Marker

Offset

6

Off

M280

290

Marker

Offset

7

On

M283

291

Marker

Offset

7

Off

M282

292

Marker

Offset

8

On

M285

293

Marker

Offset

8

Off

M284



Unsupported ESSI Codes

ESSI CODE

DESCRIPTION

103+Name

Stop Current Program/ Load New Program

237

X

Sign

Toggle

238

Y

Sign

Toggle

239

X and Y Swap and Toggle

266

Table

1

Select

267

Table

2

Select

268

Table

3

Select

269

Table

4

Select

276

Internal

Variable

Load

277

External

Variable

Load

278

X

Axis

Home

279

Y

Axis

Home

280

X

Home

Return

281

Y

Home

Return


The unsupported ESSI codes above are ignored when read. Some of these codes may be supported
in the future. Any ESSI codes that are not listed above will result in a translator error upon loading
the ESSI program.

Advertising
This manual is related to the following products: