Installation & Setup Guide

CNC/Tracer

This output is used to control a CNC relay. The CNC relay
determines whether the control, tracing system or joystick is
commanding the amplifiers. This output is deactivated whenever the
control is off, in Teach Trace mode or is disabled. Otherwise it is
always activated.


Marker / Marker Enable

This output is used to activate an external marking device. It can only
be activated by the appropriate “M” code in the part program. Refer
to Appendix A in the operator’s manual for a complete description of
appropriate “M” code commands.


Cut Control

This output is used to enable the cutting oxygen in oxy fuel mode or
start the plasma system in plasma mode. This output can also be
used to activate a marking device.


Low Preheat Control

The Low Preheat Control output is used to enable the low preheat
gas when cutting in oxy fuel mode. It is activated for the “Low
Preheat Time” when initiating a cut.


Preheat Control

This output is used to enable the high preheat gas when cutting in
oxy fuel mode. It is activated for the “High Preheat Time” when
initiating a cut.


Key Press Indicator

The Key Press Indicator output is activated whenever a key is
pressed on the control.


Motion Indicator

The Motion Indicator output is activated whenever the control is
commanding machine motion.


Plasma Select

The Plasma Select output is activated whenever the control is in the
Plasma cutting mode.


Bleed Off Gas

The Bleed Off Gas Output is used by the Oxy fuel cut logic to send
an output to the Oxy torch to purge gases at the end of a cut. This
Output is on for the duration of the Bleed Off Time selected in
setups.


Pierce Control

The Pierce Control Output is used by the Plasma and Oxy fuel cut
logic to send an output to the torch during the pierce. This Output is
on for the duration of the Pierce Time selected in setups.


Turn ON / Off Supply

The Turn ON OR Turn Off Supply Output is used by the Optional
APC (Automated Process Controller) to turn On or Off the plasma
supply through the control


N2 Select

The Turn On Supply Output is used by the Optional APC (Automated
Process Controller) to enable the use of nitrogen while cutting.


Drive Enable

The Drive Enable Output is used to enable the Drives during normal
functions and to disable the Drives during fault conditions.


Shutter Open

The Shutter Open Output is used exclusively with the Laser
cut logic and is used to open the Laser Shutter for use.


Assist Gas

The Assist Gas Output is used exclusively with the Laser cut logic
and is used to activate the Assist gas.