Hypertherm HTA Rev 6.00 Install Guide User Manual

Page 200

Advertising
background image

188

Installation & Setup Guide

I/O Connector J6

Pin Description Default

I/O

Description

1

Input 17

Gas Control Read Complete

2

Input 18

Gas Control Error

3

Input 19

Raise Torch 1

4

Input 20

Lower Torch 1

5

Input 21

Enable THC 1

6

Input 22

Raise Torch 2

7

Input 23

Lower Torch 2

8

Input 24

Enable THC 2

9 Input

25

Spare

10 Input

26

Spare

11

Input 27

Spare

12

Input 28

Spare

13

Input 29

Spare

14

Input 30

Spare

15

Input 31

Spare

16

Input 32

Spare

17 +24

VDC

N/A

18 +24

VDC

N/A

19 Chassis

Ground

N/A

20

Output 17

Remote Air Plasma

21

Output 18

Remote H35/N2 Plasma

22

Output 19

Remote O2 Plasma

23

Output 20

Gas Flow Set 1

24

Output 21

Gas Flow Set 2

25

Output 22

Gas Flow Set 4

26

Output 23

Gas Flow Set 8

27

Output 24

Gas Flow Set 10

28

Output 25

Gas Flow Set 20

29

Output 26

Gas Flow Set 40

30

Output 27

Gas Flow Set 80

31

Output 28

Gas Flow Set 100

32

Output 29

Valve Select 1

33

Output 30

Valve Select 2

34

Output 31

Valve Select 4

35

Output 32

Valve Select 8

36

+24 VDC Common

37

+24 VDC Common


Mating Connector
Connector: 37C D-Sub Amp # 205210-3 or equivalent
Backshell: Amp #748676-4 or equivalent
Pins: Amp #5-66507-9 ( 24-28 AWG ) or equivalent


Note: Additional I/O for the Voyager II™ will be available through use of optional Analog Input cards.
Additional information on the Optional Analog Input Cards is available in the Sensor™ THC section of
this guide.

Please contact your control vendor for more information on how the Analog Input Card may be
configured in your control.