Hypertherm HTA Rev 6.00 Install Guide User Manual
Page 174

162
Installation & Setup Guide
Message Command Type
>20< This command delays the part program until all bytes have been transmitted, then optionally
waits the Delay Time, if specified.
>21< A message is sent concurrent to execution of the part program and no delay is encountered.
No acknowledge is required.
>22< The message is sent with a suspension of the program during transmission as in option
one, but an Acknowledge from the external device (ACK = Hexadecimal 06 ) is required
before the part program can continue. A Non-Acknowledge (NAK = Hexadecimal 15 )
response from the external device will prompt a retransmit of the message from the
control.
An optional Time Out value may be added to the program code. If no Time Out code is
used in the program code the Default time out value at the Ports setup screen will be
used. Additionally, an optional automatic retry feature may be enabled at the Ports
setup screen.
With the automatic retry feature the message will automatically be retransmitted if no
response is detected. The retry is executed after the Time Out value has elapsed. The
number of retries can be defined on the Ports configuration screen.
Optional Format Value
Specialty characters for the format may be sent in addition to command string.
Specialty Characters Supported
HEX Name Description
01
SOH
Start of Header
02
STX
Start of Text
03
ETX
End of Text
04
EOT
End of Transmission
0A LF
Line
Feed
0D CR
Carriage
Return
BCC
“Exclusive Or” Check Byte
Note: Checksum is always an 'Exclusive OR' of the Data ONLY as it does not include any of the
'Format' chars including the CR/LF option.