Hypertherm HTA Rev 6.00 Install Guide User Manual

Page 154

Advertising
background image

142

Installation & Setup Guide

Unsupported EIA Codes ( cont. )

EIA CODE

DESCRIPTION

G277

External

Variable

Load

G278

X

Axis

Home

G279

Y

Axis

Home

G280

X

Home

Return

G281

Y

Home

Return


M22

PLC

Control

Code

M75

PLC

Control

Code

M210

X

Sign

Toggle

M211

Y

Sign

Toggle

M212

X and Y Swap and Toggle

M231

Aux.

State

Reset

M261

Aux.

Torch

Master

On

M262

Aux.

Torch

Master

Off


The unsupported EIA codes previously noted are ignored when read. Some of these codes may be
supported in the future. Any EIA codes that are not listed above will result in a translator error upon
loading the EIA program. Known EIA codes that will not be accepted include, but are not limited to:

Pvalue

Program

Number

Dvalue

Indexed

Kerf

Operations

Vvalue

Internal

Variable

Load


EIA Comments
Comments may be placed into the part program to be displayed on screen and viewed by the
operator. The comment line must first be preceded by a program stop command (EIA M00 code or
ESSI 0 code).

EIA Example:

M00 – Pauses Program
(Comment) – Text to be displayed

Advertising
This manual is related to the following products: