Installation & Setup Guide

Non – Printing Characters
Non Printing Characters are supported through use of a pair of two printing codes to equal the non-
printing code. This pair of characters is retained in the program code but sent as single 8-bit code
when transmitted.

There are three types of character pairs and each performs a different operation based on the first
character of the pair. This produces a single modified character for transmission.

Character Options

1) The “&” two-character pair clears the 0x40 bit from the 2

nd

character code value.

2) The “!” two-character pair clears the 0x40 bit and sets the 0x80 bit set in the 2

nd

character

code.

3) The “$” two-character pair clears the 0xC0 bit in the 2

nd

character.


To transmit the single character with a value 0x01, use the two character sequence ”&A”. This
converts the “A” value of 0x41 to 0x01 by clearing the 0x40 bit. To transmit 0x81, use “!A” or to
transmit )xC1 use “$A”.


Exceptions / Additions
As the “&”, “!” and “$” are used as key indicators for the Non-print characters, there is a special format
used when these characters are used as a print character in the message text. Simply use the
character twice. “&&” = “&”

The ESSI style part program uses several unique characters which requires special two character
codes to be used. For example, the message code “&K” in the part program will transmit the code
value of 0x2B which is the ASCII code for the plus sign (+). In order to send the + character the code
“&K” must be used.

The following are unique codes used in WORD ADDRESS and ESSI programs

Code Code

Value Description

&’

0x20=space

At end of ESSI program

&h

0x28 = “(“

To transmit “(” from WORD ADDRESS program

&i

0x29 = “)“

To transmit “)” from WORD ADDRESS program

&?

0x7F = DEL

Non-printable DELETE code

&K

0x2B = “+”

To transmit “+” from ESSI program

Advertising