This parameter defines the machine motion that will occur when the

↑ arrow key is pressed during

manual mode.

Right Direction
This parameter defines the machine motion that will occur when the

→ arrow key is pressed during

manual mode.

Dual Gantry Installed
Selecting Yes will enable the Dual Gantry axis and allows configuring of that axis.

CBH Installed
Selecting Yes will enable the Contour Bevel Head axis and allows configuring of that axis.

X and Y Motor/Encoder
Selecting this feature as Swapped will internally swap the X and Y Axis encoder signals. This feature
simplifies the installation to systems with alternate wiring configurations.

Key Logging
The Key Logging feature is used as a troubleshooting diagnostic tool to record key presses made at
the control during operation. When enabled, all key presses and application faults will be saved to a
daily log file that may be sent to the control manufacturer for evaluation. The files may be retrieved
and stored to diskette through the Files screen at the control. Please refer to the Files Screen
information provided in the operator’s guide for additional information on this feature.

Table Size
Enter a value for the active cutting area for the X and Y axis. These values are used to limit the Plate
size parameter in the cutting setup screen to the maximum size of the table.


THCs Installed
The THC Installed parameter defines the total number of Sensor™ THC Axes assigned for operation
at the control.

THC Installed On Axis / Analog
This setup parameter is used to define the THC Axis for use. The user can select which axis the THC
is to be commanded on, the analog input to use ( arc voltage feedback ) and which plasma.

THC On
The THC On parameter is used to indicate which processes are using Sensor™ THCs on the
control. This does not assign a process to a specific THC but rather updates the selected process
screens to enable any specific Sensor™ THC features. Refer to the Sensor™ THC appendix of this
guide for additional information on the setup and use of the Sensor™ THC.

Ignore Torch Collision During IHS
The allows the user to ignore the torch collision input during the initial height sense cycle. This may
be advantageous for some THC mechanics.

Command THCs Installed
The Command

®

THC selection is used to enable the Command THC serial Link. For more

information on this feature, please refer to the Command

®

THC section of this guide.