Installation & Setup Guide

Station Selects may be overridden by manual inputs by setting the Station Select Override feature in
Cutting Setups to disabled.

Process Selects may be overridden by manual inputs by setting the Process Select Override feature
in Cutting Setups to disabled.


Overview
First press the Stations 1-4 or Station 5-8 Softkey to access the desired station. Select the
appropriate Lifter selection for the desired station from the list of available Lifter types. Next select
the appropriate tool ( Plasma Power Supply / Marker Tool ) selection for that station from the list of
available tools in the Plasma and Marker Process fields. The tool selection should reflect the actual
tools in use for that individual Lifter. The Station may be configured so that all four Plasma and
Marker Processes operate on one Station or distributed throughout all 8 stations. If needed, the
Reset Softkey may be used to reset or clear all Station setup parameters setting the values to “None”.



Selections made for the four processes and THC designations may limit the overall configuration.
Additionally, selection of some of certain power supplies may also limit configuration.