Installation & Setup Guide

EIA CODE

DESCRIPTION

G59 Vvalue Fvalue

Sets the Plasma Supply current through Outputs or Serial Link for Vprocess
(504,514,524,534 ) at Fcurrent value

V504 – Current Setting Plasma 1

V514 – Current Setting Plasma 2

V524 – Current Setting Marker 1

V534 – Current Setting Marker 2

G82

Oxy-Fuel Cut Mode

G83

Oxy-Fuel Cut Mode Contour Bevel Head

G84 Plasma

Cut

Mode

G85

Plasma Cut Mode Contour Bevel Head

G90

Absolute Programming Mode

G91 Incremental

Programming

Mode

G92

Set Axis Presets

G97

Program

Repeat

Pointer

G97 Tvalue

Program Repeat Pointer. Executes the repeat T times

G98

Repeat at G97, or start of program if no G97

G99

Part

Options


M00

Program

Stop

M01

Optional Program Stop (uses Setup Parameter)

M02

End

of

Program

M07

Cutting

Device

On

M08

Cutting

Device

Off

M09

Enable

Marker

1

M10

Disable

Marker

1

M11

Marker

Offset

1

On

M12

Marker

Offset

1

Off

M13

Enable

Marker

2

M14

Disable

Marker

2

M15

Cut

On

M16

Cut

Off

M17

Oxy

Gas

On

M18

Oxy

Gas

Off

M19

Cancel

All

Stations

M26

Station

Select

On

M27

Station

Select

Off

M28

CBH / Rotator Disable

M29

CBH

Rotator

Enable

M30

End of Program (same as M02)

M31

Reset

Functions

(Cut

Off, Marker Off, Kerf Off)

M32

Unclamp / Unlock All Stations

M33

Unclamp / Lock All Stations

M34

Clamp / Unlock All Stations

M34Tvalue

Clamp / Unlock ‘T” Station, where T = 1 through 19

M35

Clamp / Unlock All Stations Mirror

M35Tvalue

Clamp / Unlock Mirror “T” Station, where T = 1 through 19

M36 Tvalue

Process Select “T” where T value selects the process
1- Plasma

1

2- Plasma

2

3- Marker

1

4- Marker

2

5- Laser

M37 Tvalue (1-20)

Select Station “T” where T = 1 through 20