Section 3: Diagnostics

23

Rail Negative Hardware Overtravel Reached
This message is displayed whenever the control detects a negative limit switch in the Rail axis. This
can also occur if the limit switch input is set for the wrong polarity or the limit switch wiring is not
properly connected. If the Rail axis did trip the negative limit switch, use Manual mode to jog the Rail
axis away from the limit switch.

Transverse Positive Software Overtravel Reached
This message is displayed whenever the Transverse axis position is greater than the Maximum
Travel Limit setup parameter for the Transverse axis. When this occurs, use Manual mode to jog the
Transverse axis to a position within the Travel Limit setup parameters.

Rail Positive Software Overtravel Reached
This message is displayed whenever the Rail axis position is greater than the Maximum Travel Limit
setup parameter for the Rail axis. When this occurs, use Manual mode to jog the Rail axis to a
position within the Travel Limit setup parameters.

Transverse Negative Software Overtravel Reached
This message is displayed whenever the Transverse axis position is less than the Minimum Travel
Limit setup parameter for the Transverse axis. When this occurs, use Manual mode to jog the
Transverse axis to a position within the Travel Limit setup parameters.

Rail Negative Software Overtravel Reached
This message is displayed whenever the Rail axis position is less than the Minimum Travel Limit
setup parameter for the Rail axis. When this occurs, use Manual mode to jog the Rail axis to a
position within the Travel Limit setup parameters.

Dual Gantry Skew Error Exceeded
This error message is displayed when the control has detected a position error fault between the two
drive axes on the dual gantry. It also may appear if the position feedback loops are not operating
properly, or the machine is being commanded to move or accelerate faster than it is capable. To
correct this problem, either increase the Skew Error Tolerance Setup parameter in the machine
setups screen, re-tune the system, decrease the maximum machine speed setup parameter or the
acceleration rate setup parameter.

Need Station Selection
The Need Station Selection error message is displayed if the input for a station or process has not
been activated. Example: When cutting in Plasma mode, a Plasma 1 or Plasma 2 input may be
required to execute the selected Plasma cut process.

Buffer Time Out
This may appear if there is an instance where the motion buffer is full and cannot record the data
being saved. This error allows the operator stop the motion back up on path to the last pierce and
start over without a position error. This error should be reported to the control vendor.

CNC Time Out
This is a general error that may appear if there is an instance when any buffer is full and cannot
record the data being saved. This error allows the operator stop the motion back up on path to the
last pierce and start over. This error should be reported to the control vendor.

Unable to Find HASP
The HASP is Hardware protection key ( dongle ) that enables the software and features for use. If
the HASP is not installed the control will not work. If this message appears and the hardware key is
in place, please contact your control vendor for assistance.