Mild steel, Plasma / o, Shield 30 a cutting – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 109: Metric, English, Marking

Advertising
background image

OPERATION

HPR260 Auto Gas

Instruction Manual

4-15

5

Mild steel

O

2

Plasma / O

2

Shield

30 A Cutting

220194

220173

220192

220313

220180

220193

*Pierce complete is recommended for these thicknesses

Note: Air must be connected to use this process. It is used as the preflow gas

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma Shield Plasma Shield Plasma Shield

mm

Volts

mm

mm/m

mm

factor %

seconds

O

2

O

2

78

17

94

17

0.5

114

1.3

5355

2.3

180

0.1

0.8

115

4225

0.2

1

116

3615

0.3

1.2

117

2865

1.5

119

2210

35

7

2

120

1.5

1490

2.7

0.4

2.5

122

1325

75

3*

123

1160

0.5

4*

125

905

0.7

6*

128

665

1.0

Metric

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma Shield Plasma Shield Plasma Shield

in

Volts

in

ipm

in

factor %

seconds

O

2

O

2

78

17

94

17

.018

114

0.050

215

0.090

180

0.1

.024

200

.030

115

170

0.2

.036

116

155

0.3

.048

117

110

.060

119

85

35

7

.075

120

0.060

60

0.110

0.4

.105

122

50

75

.135*

123

40

0.5

3/16*

128

30

0.7

1/4*

25

1.0

English

Select

Gases

Set

Preflow

Set

Cutflow

Amperage

Torch-to-Work

Distance

Marking

Speed

Arc

Voltage

Amps

mm

in

mm/min

ipm

Volts

N

2

N

2

10

10

10

10

15

2.5

0.100

6350

250

105

Marking

Mild steel

O

2

Plasma / O

2

Shield

30 A Cutting

Flow rates – lpm/scfh

O

2

Air

Preflow

0 / 0

43 / 90

Cutflow

25 / 52

0 / 0

Advertising