Command table (10 of 13) – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 260

Advertising
background image

APPENDIX B – CNC INTERFACE PROTOCOL

HPR260 Auto Gas

Instruction Manual

b-15

Command table (10 of 13)

ID

Command

System

Description

114

READ_INPUTS

Manual gas system
Auto gas system

This command will return the status of inputs to the PC board.
Data:
None

Return value:
1 = on, 0 = off

Power Supply
Serial program
Plasma start
Hold ignition
Phase OK
Arc detect
Pierce complete
Corner current
Redundant start
Serial ID0
Serial ID1
Serial ID2
Dipswitch #1
Dipswitch #5
Dipswitch #6
Dipswitch #7
Dipswitch #8
Chopper A overcurrent
Chopper B overcurrent
Sample:
>11496<
>114000000000000000000F6<

117

READ_GAS_INPUTS_FROM_PS Manual gas system

Auto gas system

This command will allow the CNC to query the gas console I/O
by sending the command to the serial port on the power supply
control board.

Data:
None

Return value:
1 = on, 0 = off

Manual Gas Console
Error select
Status select
Test preflow
Test cutflow
Serial ID bit 0
Serial ID bit 1
Serial ID bit 2

Auto Gas Console
Metering dipswitch 2
Metering dipswitch 3
Metering dipswitch 4
Select dipswitch 1
Select dipswitch 2
Select dipswitch 3
Select dipswitch 4
Metering dipswitch 1

Sample:
>11799<
>1170000000E9<