Aluminum, H35 plasma / n, Shield 260 a cutting – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 295: Marking, English, Metric

Advertising
background image

APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS

c-26

HPR260 Auto Gas

Instruction Manual

Aluminum

H35 Plasma / N

2

Shield

260 A Cutting

Flow rates – lpm/scfh

H35

N

2

Preflow

0 / 0

127 / 270

Cutflow

33 / 70

118 / 250

Plasma Shield Plasma Shield Plasma

Shield

mm

Volts

mm

factor %

seconds

6

170

11.0

100

0.2

10

170

10.0

100

0.4

12

162

0.5

15

163

0.6

20

166

0.6

25

174

11.0

150

0.8

32

175

38

176

44

183

50

190

Plasma Shield Plasma Shield Plasma

Shield

in

Volts

in

factor %

seconds

1/4

170

0.450

100

0.2

3/8

170

0.400

100

0.4

1/2

162

0.5

5/8

163

0.6

3/4

166

0.6

1

174

0.450

150

0.8

1-1/4

175

1-1/2

176

1-3/4

183

2

190

Marking

Amperage

Amps

mm

in

mm/min ipm

N

2

N

2

10

10

10

10

18

2.5

0.100

6350

250

Marking

Speed

Select

Gases

Set

Preflow

Set

Cutflow

Torch-to-Work

Distance

Volts

120

N/A

45

25

14

0.330

110

130

90

0.400

250

0.300

190

75

60

in

ipm

H35

N

2

12

60

76

69

0.450

280

English

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

N/A

1150

670

390

8.5

110

3720

2230

10.0

6120

7.6

5160

1930

1510

mm

mm/m

H35

N

2

12

60

76

69

11.0

7200

Metric

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Arc

Voltage

220407

220398

220307

220344

220405

220406

Advertising