APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS

c-6

HPR260 Auto Gas

Instruction Manual

Mild steel

O

2

Plasma / Air Shield

260 A Cutting

220440

220398

220435

220433

220436

220439

Flow rates – lpm/scfh @ 3/4" setting

O

2

Air

Preflow

0 / 0

130 / 275

Cutflow

42 / 88

104 / 220

Plasma Shield Plasma Shield Plasma Shield

mm

Volts

mm

factor %

seconds

6

150

10

150

12

150

0.4

15

155

0.5

20

159

0.6

22

166

0.7

25

171

0.8

28

170

0.9

32

172

1.0

38

174

1.2

44

185

50

188

58

193

64

202

Plasma Shield Plasma Shield Plasma Shield

in

Volts

in

factor %

seconds

1/4

150

3/8

150

1/2

150

0.4

5/8

155

0.5

3/4

159

0.6

7/8

166

0.7

1

171

0.8

1-1/8

170

0.9

1-1/4

172

1.0

1-1/2

174

1.2

1-3/4

185

2

188

2-1/4

193

2-1/2

202

Marking

Amperage

Amps

mm

in

mm/min ipm

N

2

N

2

10

10

10

10

18

2.5

0.100

6350

250

N/A

0.3

8.5

300

0.3

9.0

250

9.5

200

N/A

0.350

250

0.380

200

135

Select

Gases

Set

Preflow

Set

Cutflow

Torch-to-Work

Distance

Marking

Speed

Volts

58

54

58

84

76

80

12

8

65

0.140

0.190

55

45

35

22

15

84

76

80

4.8

54

2.8

58

3.6

75

250

in

ipm

180

145

115

90

0.110

O

2

Air

22

English

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Pierce Delay

Time

405

290

195

Cutting

Speed

300

0.330

3130

2170

895

580

1685

1445

1135

Initial Pierce

Height

mm

mm/m

O

2

Air

22

6500

4440

3850

1930

58

Metric

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Arc

Voltage