Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 309

Advertising
background image

APPENDIX D – BEVEL CUTTING

HPR260 Auto Gas

Instruction Manual

d-13

6. Connect the plasma vent hose (white).

7. Connect the coolant return hose (red).

8. Connect the plasma gas hose (black).

9. Connect the shield gas hose (blue).

10. Slide the mounting sleeve over the connections and screw it onto the torch quick-disconnect.

11. Slide the spiral wrap into the torch sleeve, about 50 mm (2 in). There will be a gap between the spiral wrap and the

braided cover. The spiral wrap and braiding do not get clamped in place.

Note: The connectors in steps

6–9 are push-to-connect
fittings.

To make a connection, slide
the hose fitting into the
appropriate connector until it
stops.

To disconnect a fitting, pull
back on the connector-collar
and pull out the hose fitting.

connector-collar

Spiral wrap

Braided cover

5

Advertising