Cnc controller requirements -4, Cnc controller requirements – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 98

Advertising
background image

OPERATION

4-4

HPR260 Auto Gas

Instruction Manual

CNC controller requirements

Base required elements

The following elements should be able to be displayed and adjusted on the CNC for setup and basic system
information. The plasma system needs this group for basic setup and operation capability.

1. Remote ON/OFF
2. Ability to display and adjust the basic plasma process set-points (command ID #95)

a. Current set point
b. Plasma preflow
c. Plasma cutflow
d. Shield preflow
e. Shield cutflow
f. Plasma gas type
g. Shield gas type
h. Gas mixing set-points

3. Display basic system information

a. System error code
b. Gas and PS firmware version

4. Manual pump control

Required real time elements

The following elements should be able to be displayed in real time while cutting. This is necessary for trouble shooting
and diagnostic purposes.

5. Display line voltage
6. Display chopper current
7. Display work lead current
8. Display system status code
9. Display chopper temperature

10. Display transformer temperature
11. Display coolant temperature
12. Display coolant flow
13. Display pressure transducers

Required diagnostic elements

These elements provide additional diagnostic capability to the system for troubleshooting gas-delivery problems. The
CNC should be capable of executing these commands and displaying the relevant information for the respective test
according to the serial protocol guidelines.

14. Test preflow gases
15. Test cutflow gases
16. Inlet leak test
17. System leak test
18. System flow test

Advertising