SPECIFICATIONS

HPR260 Auto Gas

Instruction Manual

2-5

5

Power supply

133.4 mm

5.3"

1181.1 mm

46.5"

1143.0 mm

45.0"

803.3 mm

31.6"

554.7 kg

1223 lb

General
Maximum OCV (U

0

)

311 VDC

Maximum output current (I

2

)

260 Amps

Output voltage (U

2

)

50 – 175 VDC

Duty cycle rating (X)

100% @ 45.5 kw, 40° C (104° F)

Ambient temperature/Duty cycle

Power supplies will operate between -10° C and +40° C (+14° and 104° F)

Power factor(cos

ϕ

)

0.98 @ 260 ADC output

Cooling

Forced air (Class F)

Insulation

Class H

Part

number

AC Voltage

(U

1

)

Phase

Frequency

(Hz)

Amperage (I

1

)

Regulatory

approval

Power kW

(+/- 10%)

(U

1

x I

1

x 1.73)

078187

200/208

3

50/60

149/144

CSA

51.6

078202

220

3

50/60

136

CSA

51.6

078188

240

3

60

124

CSA

51.6

078192

380

3

50/60

79

CCC

51.6

078186

400

3

50/60

75

CE/GOST-R

51.6

078189

440

3

50/60

68

CSA

51.6

078190

480

3

60

62

CSA

51.6

078191

600

3

60

50

CSA

51.6

Note: Software verification is needed for field upgrade units. New systems ship with revision J software or