OPERATION

HPR260 Auto Gas

Instruction Manual

4-41

Aluminum

N

2

Plasma / Air Shield

260 A Cutting

220407

220398

220307

220344

220405

220406

5

Metric

English

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma Shield Plasma Shield Plasma Shield

mm

Volts

mm

mm/m

mm

factor %

seconds

N

2

Air

12

49

74

56

6

172

6.4

7900

9.0

140

0.2

10

171

4930

0.4

12

164

4.0

4290

8.0

200

0.5

15

165

3330

0.6

20

171

1940

25

177

1440

11.0

260

0.8

32

191

940

Edge start

38

195

520

44

202

320

50

205

215

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma Shield Plasma Shield Plasma Shield

in

Volts

in

ipm

in

factor %

seconds

N

2

Air

12

49

74

56

1/4

172

0.250

300

0.350

140

0.2

3/8

171

200

0.4

1/2

164

0.160

160

0.320

200

0.5

5/8

165

120

0.6

3/4

171

80

1

177

55

0.420

260

0.8

1-1/4

190

40

Edge start

1-1/2

195

20

1-3/4

202

12

2

205

8

Select

Gases

Set

Preflow

Set

Cutflow

Amperage

Torch-to-Work

Distance

Marking

Speed

Arc

Voltage

Amps

mm

in

mm/min

ipm

Volts

N

2

N

2

10

10

10

10

18

2.5

0.100

6350

250

120

Marking

Flow rates – lpm/scfh

N

2

Air

Preflow

125 / 265

0 / 0

Cutflow

50 / 105

113 / 240