Power supply to cnc interface cable -24, Optional multi-system cnc interface cable -24, Power supply to cnc interface cable – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 73: Optional multi-system cnc interface cable

Advertising
background image

INSTALLATION

3-24

HPR260 Auto Gas

Instruction Manual

5

Wire

Input/

Input/

color

Pin #

Output

Signal name

Function

Output

Notes

Black

1

Input

Rx -

RS-422 serial receiver

Output

Red

20

Input

Rx +

RS-422 serial receiver

Output

Black

2

Output

Tx -

RS-422 serial transmitter

Input

Green

21

Output

Tx +

RS-422 serial transmitter

Input

Black

3

RS-422 ground

RS-422 serial ground

Blue

22

None

Not used

Black

4

Output

Motion 1 E (-)

Notifies the CNC that an arc transfer has occurred and to begin

Input

2 & 3

Yellow

23

Output

Motion 1 C (+)

machine motion once the CNC’s pierce delay has timed out.

Input

Black

5

Output

Error E (-)

Notifies the CNC that an error has occurred.

Input

2

Brown

24

Output

Error C (+)

Input

Black

6

Output

Rampdown error E (-)

Notifies the CNC that a rampdown error has occurred

Input

2

Orange

25

Output

Rampdown error C (+)

Red

7

Output

Not ready E (-)

Notifies the CNC that the plasma system is not ready to fire an arc

Input

2

White

26

Output

Not ready C (+)

Red

8

Output

Motion 2 E (-)

Notifies the CNC that an arc transfer has occurred and to begin

Input

2 & 3

Green

27

Output

Motion 2 C (+)

machine motion once the CNC’s pierce delay has timed out.

Input

Red

9

Output

Motion 3 E (-)

Notifies the CNC that an arc transfer has occurred and to begin

Input

2 & 3

Blue

28

Output

Motion 3 C (+)

machine motion once the CNC’s pierce delay has timed out.

Input

Red

10

Output

Motion 4 E (-)

Notifies the CNC that an arc transfer has occurred and to begin

Input

2 & 3

Yellow

29

Output

Motion 4 C (+)

machine motion once the CNC’s pierce delay has timed out.

Input

Red

11

None

Not used

Brown

30

None

Not used

Red

12

Input

Corner -

CNC Notifies the plasma system that a corner is approaching and to

Output

1

Orange

31

Input

Corner +

reduce cut current (Cut current is CNC selectable or defaults to 50%.

Output

of cut current)

Green

13

Input

Pierce -

CNC Notifies the plasma system to maintain the shield preflow until

Output

1

White

32

Input

Pierce +

the CNC releases the signal.

Green

14

Input

Hold -

Not required without CommandTHC. CommandTHC requires signal

Output

1

Blue

33

Input

Hold +

to preflow gases during IHS.

Green

15

Input

Start -

CNC initiates the plasma arc.

Output

1

Yellow

34

Input

Start +

Output

Green

16

None

Not used

Brown

35

None

Not used

Green

17

None

Not used

Orange

36

Power ground

Ground

White

18

Power ground

Ground

Black

37

CNC +24 VDC

Available 24 VDC (200 milliamps maximum) See notes

4

19

CNC + 24 VDC

Not connected

Power supply to CNC interface cable

8

To J 300

Power supply

CNC

Optional multi-system CNC interface cable

(see schematics for installation information)

9

Part no.

Length

Part no.

Length

123210

3 m (10 ft)

123741

25 m (82 ft)

123211

4.5 m (15 ft)

123742

35 m (115 ft)

123022

7.5 m (25 ft)

123220

45 m (150 ft)

123214

10 m (35 ft)

123852

60 m (200 ft)

123023

15 m (50 ft)

123853

75 m (250 ft)

123851

20 m (65 ft)

Advertising