Aluminum, Air plasma / air shield 130 a cutting, Marking – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 289: English, Metric

Advertising
background image

APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS

c-20

HPR260 Auto Gas

Instruction Manual

Aluminum

Air Plasma / Air Shield

130 A Cutting

220198

220173

220181

220176

220179

220197

Note: This process produces a rougher cut edge with larger average angles than the 130A, H35/N

2

process

Flow rates – lpm/scfh

Air

Preflow

73 / 154

Cutflow

78 / 165

Plasma Shield Plasma Shield Plasma Shield

mm

Volts

mm

factor %

seconds

6

153

5.6

0.2

10

154

0.3

12

156

0.5

15

158

6.6

0.8

20

162

7.0

1.3

25

172

Plasma Shield Plasma Shield Plasma Shield

in

Volts

in

factor %

seconds

1/4

153

0.220

0.2

3/8

154

0.3

1/2

156

0.5

5/8

158

0.260

0.8

3/4

162

0.280

1.3

1

172

Amperage

Amps

mm

in

mm/min ipm

N

2

N

2

10

10

10

10

18

2.5

0.100

6350

250

Marking

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Pierce Delay

Time

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Torch-to-Work

Distance

Arc

Voltage

0.110

in

0.120

38

75

27

English

N/A

0.130

0.160

20

0.140

60

200

45

40

Metric

30

0.240

ipm

Cutting

Speed

Initial Pierce

Height

90

Air

Air

19

Air

Air

3.5

4.0

725

525

1225

1050

Select

Gases

Set

Preflow

N/A

200

2.8

19

38

75

27

3.0

6.0

mm

mm/m

3.3

2370

1465

Marking

Speed

Volts

120

Select

Gases

Set

Preflow

Set

Cutflow

Torch-to-Work

Distance

Arc

Voltage

Advertising