Examples of input circuits – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 76

Advertising
background image

INSTALLATION

HPR260 Auto Gas

Instruction Manual

3-27

3

Examples of input circuits

Output from

CNC/PLC

External relay

(AC or DC)

1. Relay interface

+24 VDC

HPR

Power

ground

2. Optocoupler interface

CNC/PLC

+24 VDC

HPR

Power

ground

Transistor-output
optocoupler

12V-24 VDC

CNC/PLC

+24 VDC

HPR

Power

ground

Power

ground

Active-high drive

3. Amplified-output interface

Note: The external relay's life may be improved by adding a

metallized-polyester capacitor (0.022µF 100V or higher) in

parallel with the relay contacts.

Advertising