Stainless steel, Plasma / n, Shield 200 a cutting – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 122: Metric english, Marking

Advertising
background image

OPERATION

4-28

HPR260 Auto Gas

Instruction Manual

4

Stainless steel

N

2

Plasma / N

2

Shield

200 A Cutting

220345

220398

220307

220344

220342

220343

Metric

English

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma Shield Plasma Shield Plasma Shield

mm

Volts

mm

mm/m

mm

factor %

seconds

N

2

N

2

20

42

84

42

10

160

3.8

2700

7.6

200

0.5

12

161

2400

0.6

15

163

1800

0.8

20

167

1000

1.0

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma Shield Plasma Shield Plasma Shield

in

Volts

in

ipm

in

factor %

seconds

N

2

N

2

20

42

84

42

3/8

160

0.150

110

0.300

200

0.5

1/2

161

90

0.6

5/8

163

65

0.8

3/4

167

45

1.0

Select

Gases

Set

Preflow

Set

Cutflow

Amperage

Torch-to-Work

Distance

Marking

Speed

Arc

Voltage

Amps

mm

in

mm/min

ipm

Volts

N

2

N

2

10

10

10

10

18

2.5

0.100

6350

250

140

Marking

Flow rates – lpm/scfh

N

2

Preflow

111 / 235

Cutflow

137 / 290

Advertising