Remote on/off switch -28, Remote on/off switch (provided by customer), Danger – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 77

Advertising
background image

INSTALLATION

3-28

HPR260 Auto Gas

Instruction Manual

1. Locate terminal block 2 (TB2) in the power supply.

2. Remove wire 1 and wire 3 as shown. These wires do not need to be reconnected.

3. Connect switch to terminals 1 and 3 as shown.

TB2 location

1

2

3

1

3

TB2

1

3

1

2

3

TB2

1

3

Note: Use a switch, relay or solid-state relay that is compatible with 24 VAC @ 100 mA. It must be a

maintained contact switch, not a momentary contact switch.

Remote ON/OFF switch (provided by customer)

5

DANGER

ELECTRIC SHOCK CAN KILL

Disconnect electrical power before performing any maintenance.
See the Safety
section in this manual for more safety precautions.

Advertising