APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS

c-16

HPR260 Auto Gas

Instruction Manual

Stainless steel

H35 Plasma / N

2

Shield

260 A Cutting

Flow rates – lpm/scfh

H35

N

2

Preflow

0 / 0

127 / 270

Cutflow

40 / 84

122 / 260

Plasma Shield Plasma Shield Plasma Shield

mm

Volts

mm

factor %

seconds

10

188

11.0

0.3

12

173

0.4

15

171

0.5

20

175

0.6

25

180

0.7

32

185

1.0

38

186

44

189

50

200

Plasma Shield Plasma Shield Plasma Shield

in

Volts

in

factor %

seconds

3/8

188

0.500

0.3

1/2

173

0.350

0.4

5/8

171

0.5

3/4

175

0.6

1

180

0.7

1-1/4

185

1.0

1-1/2

186

1-3/4

189

2

200

Marking

Amperage

Amps

mm

in

mm/min ipm

N

2

N

2

10

10

10

10

18

2.5

0.100

6350

250

75

100

0.360

English

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Select

Gases

Set

Preflow

100

120

390

270

Metric

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

mm

mm/m

H35

N

2

12

59

85

71

11.0

1870

9.0

1710

9.0

7.5

1465

1085

785

630

510

N/A

Set

Cutflow

Material

Thickness

Pierce Delay

Time

in

ipm

H35

N

2

12

59

85

71

0.450

0.350

65

0.300

55

20

120

45

30

25

N/A

15

10

Select

Gases

Set

Preflow

Set

Cutflow

Torch-to-Work

Distance

Marking

Speed

Volts

120

Arc

Voltage

220407

220398

220307

220344

220405

220406