APPENDIX B – CNC INTERFACE PROTOCOL

HPR260 Auto Gas

Instruction Manual

b-21

5

ID

Name

Description

072

AUTOMATIC GAS CONTROL BOARD
OVERTEMP

Control board has exceeded 90° C (194° F).

093

NO COOLANT FLOW

Coolant flow is less than 0.6 gpm.

099

CHOPPER1 OVERTEMP AT INIT

Chopper #1 is indicating overtemp during power-up.

100

CHOPPER2 OVERTEMP AT INIT

Chopper #2 is indicating overtemp during power-up.

101

MAGNETICS OVERTEMP AT INIT

Transformer is indicating overtemp during power-up.

102

OUTPUT CURRRENT AT INIT

Chopper current signal is active on power-up.

103

CURRENT TOO HIGH ON LEM #1

A current greater than 35 amps has been detected by current
sensor 1.

104

CURRENT TOO HIGH ON LEM #2

A current greater than 35 amps has been detected by current
sensor 2.

105

CURRENT TOO LOW ON LEM #1

A current less than 10 amps has been detected by current
sensor 1.

106

CURRENT TOO LOW ON LEM #2

A current less than 10 amps has been detected by current
sensor 2.

108

TRANSFER AT INIT

The system has detected current on the work lead during
power-up.

109

COOLANT FLOW AT INIT

Coolant flow is greater than 1.14 lpm (0.3 gpm) when pump is
off.

111

COOLANT OVERTEMP AT INIT

Coolant is indicating overtemp during power-up.

116

WATCHDOG INTERLOCK

CAN communication error.

123

MV 1 ERROR

Motor valve 1 did not move into position within 60 seconds.

124

MV 2 ERROR

Motor valve 2 did not move into position within 60 seconds.

133

UNKNOWN GAS CONSOLE TYPE

The power supply control board does not recognize the gas
console installed or has not received a CAN message identifying
the type of console installed.

134

CHOPPER 1 OVERCURRENT

Chopper 1 current feedback has exceeded 160 amps.

138

CHOPPER 2 OVERCURRENT

Chopper 2 current feedback has exceeded 160 amps.

139

PURGE TIMEOUT ERROR

The purge cycle did not complete within 3 minutes.

140

AUTO GAS PRESSURE TRANSDUCER
#1 ERROR

Faulty transducer or auto gas control PCB

141

AUTO GAS PRESSURE TRANSDUCER
#2 ERROR

Faulty transducer or auto gas control PCB

142

AUTO GAS PRESSURE TRANSDUCER
#3 ERROR

Faulty transducer or auto gas control PCB

143

AUTO GAS PRESSURE TRANSDUCER
#4 ERROR

Faulty transducer or auto gas control PCB

144

MANUAL GAS CONSOLE INTERNAL
FLASH MEMORY ERROR

Replace manual gas console control PCB

145

AUTOMATIC GAS CONSOLE INTERNAL
FLASH MEMORY ERROR

Replace auto gas console control PCB

151

SOFTWARE FAIL

Software has detected an incorrect state or condition.

152

INTERNAL FLASH ERROR

DSP memory is not working properly.

153

PS EEPROM ERROR

EEPROM memory on power supply board not working.

180

SELECTION CONSOLE CAN TIMEOUT

Power supply has not received a CAN message from the
selection console within 1 second

181

METERING CONSOLE CAN TIMEOUT

Power supply has not received a CAN message from the
metering console within 1 second