Gas regulators -43, Gas regulators – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 92

Advertising
background image

INSTALLATION

HPR260 Auto Gas

Instruction Manual

3-43

Gas regulators

Low-quality gas regulators do not provide consistent supply pressures and can result in poor cut quality and system
operation problems. Use a high-quality, 1-stage, gas regulator to maintain consistent gas supply pressure, if using liquid
cryogenic or bulk storage. Use a high-quality, 2-stage, gas regulator to maintain consistent gas supply pressure from
high pressure gas cylinders.

The high-quality gas regulators listed below are available from Hypertherm and meet U.S. Compressed Gas Association
(CGA) specifications. In other countries, select gas regulators that conform to national or local codes.

Part
Number

Description

Qty.

128544

Kit: Oxygen, 2-stage *

1

128545

Kit: Inert Gas, 2-stage

1

128546

Kit: Hydrogen (H5, H35 and methane) 2-stage

1

128547

Kit: Air, 2-stage

1

128548

Kit: 1-stage (for use with cryogenic liquid nitrogen or oxygen)

1

022037

Oxygen, 2-stage

1

022038

Inert gas, 2-stage

1

022039

Hydrogen/methane, 2-stage

3

022040

Air, 2-stage

1

022041

Line regulator, 1-stage

1

*

Kits include appropriate fittings

2-stage regulator

Single stage regulator