Command table (2 of 13) – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 252

Advertising
background image

APPENDIX B – CNC INTERFACE PROTOCOL

HPR260 Auto Gas

Instruction Manual

b-7

ID

Command

System

Description

028

READ_PLASMA_AMPS

Manual gas system
Auto gas system

Read actual power supply current

Data:
None

Return value:
Power supply current in amps

Sample:
>0289A<
>02801305E< (130 amps)

058

SET_NOMINAL_AMPS

Auto gas system

Set the power supply current in amps.

Data:
5-260 Amps (Limited to 130 amps on the HPR130)

Return value:
Actual current value set

Sample:
>05813031<
>058013061< (set 130 amps)

064

GAS_PREFLOW_TEST_START

Manual gas system
Auto gas system

Turn on the preflow gases. Not allowed when cutting.

Data:
None

Return value:
1 = accepted, 0 = not accepted

Sample:
>0649A<
>0641CB<

065

GAS_PREFLOW_TEST_STOP

Manual gas system
Auto gas system

Turn off the preflow gases. Not allowed when cutting.

Data:
None

Return value:
1 = accepted, 0 = not accepted

Sample:
>0659B<
>0651CC<

066

GAS_CUTFLOW_TEST_START

Manual gas system
Auto gas system

Turn on the cutflow gases. Not allowed when cutting.

Data:
None

Return value:
1 = accepted, 0 = not accepted

Sample:
>0669C<
>0661CD<

067

GAS_CUTFLOW_TEST_STOP

Manual gas system
Auto gas system

Turn off the cutflow gases. Not allowed when cutting.

Data:
None

Return value:
1 = accepted, 0 = not accepted

Sample:
>0679D<
>0671CE<)

Command table (2 of 13)