Aluminum, H35 and n, Plasma / n – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 130: Shield 130 a cutting, Metric english, Marking

Advertising
background image

OPERATION

4-36

HPR260 Auto Gas

Instruction Manual

Aluminum

H35 and N

2

Plasma / N

2

Shield

130 A Cutting

220198

220173

220307

220304

220179

220197

5

Metric

English

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce

Delay

Time

Plasma Shield Plasma Shield Plasma Shield

Mix

Gas 1

Mix

Gas 2

mm

Volts

mm

mm/m

mm

factor % seconds

H35

N

2

19

51

75

27

32

18

6

156

3.5

2215

7.0

200

0.3

10

158

1615

12

159

3.0

1455

6.0

0.5

15

160

1215

0.8

20

163

815

1.3

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce

Delay

Time

Plasma Shield Plasma Shield Plasma Shield

Mix

Gas 1

Mix

Gas 2

in

Volts

in

ipm

in

factor % seconds

H35

N

2

19

51

75

27

32

18

1/4

156

0.140

85

0.280

200

0.3

3/8

158

65

1/2

159

0.120

55

0.240

0.5

5/8

160

45

0.8

3/4

163

35

1.3

Select

Gases

Set

Preflow

Set

Cutflow

Amperage

Torch-to-Work

Distance

Marking

Speed

Arc

Voltage

Amps

mm

in

mm/min

ipm

Volts

N

2

N

2

10

10

10

10

18

2.5

0.100

6350

250

130

Marking

Flow rates – lpm/scfh

H35

N

2

Preflow

0 / 0

97 / 205

Cutflow

13 / 28

71 / 150

Advertising