MAINTENANCE

5-6

HPR260 Auto Gas

Instruction Manual

5

Gas system purge cycle

When the system is turned on, or the operator changes from one cut process to another, the system automatically goes
through a purge cycle. The purge cycle has 2 stages; a preflow purge and a cutflow purge.

The preflow gas flows for 8 seconds with an auto gas console, or 12 seconds with a manual gas console.

The cutflow gas flows for 8 seconds with an auto gas console, or 12 seconds with a manual gas console.

There are 2 exceptions to the cycle described above.

Exception 1 – if the operator changes from a non-fuel gas process (O

2

/Air, Air/Air, or N

2

/Air) to a fuel gas process

(H35/N

2

, or F5/N

2

) or the reverse, there will be 3 stages to the purge process. Nitrogen will purge the

gas system first, for 12 seconds. The preflow and cutflow purges will follow the nitrogen purge.

Note: error code 42 (low nitrogen gas pressure) will be displayed, if nitrogen is not connected to the gas system. If

error code 42 is not resolved in 3 minutes, it will be replaced by error code 139 (purge time-out error).

Exception 2 – no purge cycle will occur if the operator changes from any cut process to a nitrogen marking process.

Gas system valve usage

The following tables show which valves are active for each cutting process.

O

2

/O

2

process

Metering console

control board

Selection console control board

LED
number

38 39 28 37

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15 16

Preflow B4

B2

SV1

SV3

SV8

SV10

Cutflow

B3

B1 SV1

SV3

SV8

SV10

O

2

/Air

process

Metering console

control board

Selection console control board

LED
number

38 39 28 37

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15 16

Preflow B4

B2

SV1

SV3

SV8

SV10

Cutflow

B3 B2

SV1

SV3

SV8

SV10

N

2

/N

2

process

Metering console

control board

Selection console control board

LED
number

38 39 28 37

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15 16

Preflow B4

B1

SV9

SV11

Cutflow B4

B1

SV9

SV11