Aluminum, Plasma / n, Shield 200 a cutting – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 293: Marking, English, Metric

Advertising
background image

APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS

c-24

HPR260 Auto Gas

Instruction Manual

Aluminum

N

2

Plasma / N

2

Shield

200 A Cutting

Plasma Shield Plasma Shield Plasma Shield

mm

Volts

mm

factor %

seconds

10

158

0.4

12

158

0.5

15

166

0.6

20

165

0.8

Plasma Shield Plasma Shield Plasma Shield

in

Volts

in

factor %

seconds

3/8

158

0.4

1/2

158

0.5

5/8

166

0.6

3/4

165

0.8

Marking

Amperage

Amps

mm

in

mm/min ipm

N

2

N

2

10

10

10

10

18

2.5

0.100

6350

250

Marking

Speed

Volts

140

Select

Gases

Set

Preflow

Set

Cutflow

Torch-to-Work

Distance

0.350

140

120

80

50

in

ipm

N

2

N

2

22

53

73

53

0.250

200

English

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

9.0

140

3500

2350

1000

mm

mm/m

N

2

N

2

22

53

73

53

6.4

4750

Metric

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Arc

Voltage

Flow rates – lpm/scfh

N

2

Preflow

113 / 240

Cutflow

135 / 287

220345

220398

220307

220347

220342

220346

Advertising