Mild steel, Plasma / o, Shield 30 a cutting – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 271: Metric english, Marking

Advertising
background image

APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS

c-2

HPR260 Auto Gas

Instruction Manual

Mild steel

O

2

Plasma / O

2

Shield

30 A Cutting

220194

220173

220192

220313

220180

220193

Plasma Shield Plasma Shield Plasma Shield

mm

s

d

n

o

c

e

s

%

r

o

t

c

a

f

m

m

s

t

l

o

V

0.5

1

.

0

4

1

1

0.8

2

.

0

5

1

1

1

116

1.2

117

1.5

119

2

120

2.5

122

3*

5

.

0

3

2

1

4*

125

0.7

6*

128

1.0

Plasma Shield Plasma Shield Plasma Shield

in

s

d

n

o

c

e

s

%

r

o

t

c

a

f

n

i

s

t

l

o

V

.018

.024

.030

2

.

0

5

1

1

.036

116

.048

117

.060

119

.075

120

.105

122

.135*

5

.

0

3

2

1

3/16*

0.7

1/4*

1.0

Amperage

Amps

mm

in

mm/min ipm

N

2

N

2

10

10

10

10

15

2.5

0.100

6350

250

Arc

Voltage

Volts

105

Marking

Speed

Torch-to-Work

Distance

Select

Gases

Set

Preflow

Set

Cutflow

2.7

1325

1160

905

94

114

0.050

0.060

Arc

Voltage

78

17

35

75

O

2

O

2

1.5

2.3

665

5355

94

17

7

1.3

Initial Pierce

Height

Pierce Delay

Time

0.3

180

0.4

60

Metric

English

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

17

mm

mm/m

Torch-to-Work

Distance

4225

3615

2865

2210

1490

Pierce Delay

Time

in

ipm

215

0.090

Cutting

Speed

Initial Pierce

Height

85

155

170

128

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

O

2

O

2

78

75

35

180

0.1

0.3

0.4

Marking

7

17

30

25

40

50

110

200

0.110

Flow rates – lpm/scfh

O

2

Air

Preflow

0 / 0

46 / 97

Cutflow

22 / 46

0/0

*Pierce complete is recommended for these thicknesses

Note: Air must be connected to use this process. It is used as the preflow gas

Advertising