background image

OPERATION

HPR260 Auto Gas

Instruction Manual

4-23

Stainless steel

F5 Plasma / N

2

Shield

80 A Cutting

220338

220173

220339

220304

220179

220337

4

Metric

English

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma Shield Plasma Shield Plasma Shield

mm

Volts

mm

mm/m

mm

factor %

seconds

F5

N

2

33

23

65

37

4

108

3.0

2180

4.5

150

0.2

6

112

2.5

1225

3.8

0.3

10

120

3.0

560

4.5

0.5

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma Shield Plasma Shield Plasma Shield

in

Volts

in

ipm

in

factor %

seconds

F5

N

2

33

23

65

37

.135

108

0.120

105

0.180

150

0.2

3/16

110

0.110

60

0.170

0.3

1/4

112

0.100

45

0.150

3/8

120

0.120

25

0.180

0.5

Select

Gases

Set

Preflow

Set

Cutflow

Amperage

Torch-to-Work

Distance

Marking

Speed

Arc

Voltage

Amps

mm

in

mm/min

ipm

Volts

N

2

N

2

10

10

10

10

15

2.5

0.100

6350

250

95

Marking

Flow rates – lpm/scfh

F5

N

2

Preflow

0 / 0

67 / 142

Cutflow

31 / 65

55 / 116