Aluminum, H35 and n, Plasma / n – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 294: Shield 200 a cutting, Marking, English, Metric

Advertising
background image

APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS

HPR260 Auto Gas

Instruction Manual

c-25

Aluminum

H35 and N

2

Plasma / N

2

Shield

200 A Cutting

Flow rates – lpm/scfh

H35

N

2

Preflow

0 / 0

121 / 256

Cutflow

13 / 27

126 / 267

Plasma Shield Plasma Shield Plasma Shield

Mix

Gas 1

Mix

Gas 2

mm

Volts

mm factor %

seconds

10

158

0.3

12

158

0.4

15

162

0.5

20

170

0.6

Plasma Shield Plasma Shield Plasma Shield

Mix

Gas 1

Mix

Gas 2

in

Volts

in

factor %

seconds

3/8

158

0.3

1/2

158

0.4

5/8

162

0.5

3/4

170

0.6

Marking

mm

in

mm/min

N

2

N

2

10

10

10

10

2.5

0.100

6350

18

250

140

Torch-to-Work

Distance

Amps

ipm

Volts

Select

Gases

Set

Preflow

Set

Cutflow

Amperage

0.250

160

0.350

140

140

80

50

in

ipm

H35

N

2

22

53

73

53

42

20

English

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-

Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce

Delay Time

6.4

4000

9.0

140

3650

2450

1050

mm

mm/m

H35

N

2

22

53

73

53

42

20

Metric

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-

Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce

Delay Time

Marking

Speed

Arc

Voltage

220345

220398

220307

220347

220342

220346

Advertising