Aluminum, H35 plasma / n, Shield 200 a cutting – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 131: Metric english, Marking

Advertising
background image

OPERATION

HPR260 Auto Gas

Instruction Manual

4-37

4

Aluminum

H35 Plasma / N

2

Shield

200 A Cutting

220345

220398

220307

220347

220342

220346

Metric

English

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma Shield Plasma Shield Plasma Shield

mm

Volts

mm

mm/m

mm

factor %

seconds

H35

N

2

22

43

73

43

10

152

6.4

4400

9.0

140

0.3

12

150

3800

0.4

15

3000

0.5

20

159

1450

0.6

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma Shield Plasma Shield Plasma Shield

in

Volts

in

ipm

in

factor %

seconds

H35

N

2

22

43

73

43

3/8

152

0.250

180

0.350

140

0.3

1/2

150

140

0.4

5/8

110

0.5

3/4

159

70

0.6

Select

Gases

Set

Preflow

Set

Cutflow

Amperage

Torch-to-Work

Distance

Marking

Speed

Arc

Voltage

Amps

mm

in

mm/min

ipm

Volts

N

2

N

2

10

10

10

10

18

2.5

0.100

6350

250

140

Marking

Flow rates – lpm/scfh

H35

N

2

Preflow

0 / 0

113 / 240

Cutflow

34 / 72

90 / 190

Advertising