Stainless steel, H35 and n, Plasma / n – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 287: Shield 260 a cutting, Marking, English, Metric

Advertising
background image

APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS

c-18

HPR260 Auto Gas

Instruction Manual

Stainless steel

H35 and N

2

Plasma / N

2

Shield

260 A Cutting

Flow rates – lpm/scfh

H35

N

2

Preflow

0 / 0

132 / 280

Cutflow

13 / 27

163 / 345

Plasma Shield Plasma Shield Plasma Shield

Mix

Gas 1

Mix

Gas 2

mm

Volts

mm factor %

seconds

6

170

10

175

12

176

0.5

15

177

0.7

20

179

0.8

25

182

1.0

32

186

1.2

38

189

44

195

50

202

Plasma Shield Plasma Shield Plasma Shield

Mix

Gas 1

Mix

Gas 2

in

Volts

in

factor %

seconds

1/4

170

3/8

175

1/2

176

0.5

5/8

177

0.7

3/4

179

0.8

1

182

1.0

1-1/4

186

1.2

1-1/2

189

1-3/4

187

2

202

Marking

mm

in

mm/min

N

2

N

2

10

10

10

10

2.5

0.100

6350

18

250

120

Torch-to-Work

Distance

Amps

ipm

Volts

Select

Gases

30

20

15

Set

Preflow

Set

Cutflow

Amperage

40

26

0.160

150

0.320

200

55

N/A

10

0.3

90

65

65

35

in

ipm

H35

N

2

12

59

87

71

60

21

English

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-

Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce

Delay Time

40

26

920

755

510

390

270

4.0

21

0.3

2190

1790

1650

3980

8.0

200

1320

N/A

mm

mm/m

H35

N

2

12

59

87

71

60

Metric

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-

Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce

Delay Time

Marking

Speed

Arc

Voltage

220407

220398

220307

220344

220405

220406

Advertising