APPENDIX B – CNC INTERFACE PROTOCOL

b-2

HPR260 Auto Gas

Instruction Manual

Interface hardware

• The interface will use a combination of discrete signals (5 inputs, 3 outputs, and 24 VDC active low) and an

addressable RS422 interface.

• The hardware will provide 4 unique addresses, which allows 4 systems to be connected to the same CNC.

Addressing mechanism will be inside the power supply, on a PC board (Note: A total of 32 I/O (20 Inputs,
12 Outputs) points will be required for 4 systems).

• The RS422 hardware will have tri-stateable transmitter to disconnect itself from the line when not

communicating.

• Mounting holes for footprint of Command THC plasma interface board.

• Must have an interface compatible with the Command THC/HD4070.

Signal list

Signals

Signal name

Type

Description

Plasma Start

Input

When active, the plasma system will fire an arc

Machine Motion 1

Output

Indicates the arc has transferred to the plate. This signal is selected
using jumper on power supply control board. Only 1 motion signal is
needed per system. The remaining motion signals can be used to
wire multiple systems in a daisy chain configuration.

Machine Motion 2

Output

Indicates the arc has transferred to the plate. This signal is selected
using jumper on power supply control board. Only 1 motion signal is
needed per system. The remaining motion signals can be used to
wire multiple systems in a daisy chain configuration.

Machine Motion 3

Output

Indicates the arc has transferred to the plate. This signal is selected
using jumper on power supply control board. Only 1 motion signal is
needed per system. The remaining motion signals can be used to
wire multiple systems in a daisy chain configuration.

Machine Motion 4

Output

Indicates the arc has transferred to the plate. This signal is selected
using jumper on power supply control board. Only 1 motion signal is
needed per system. The remaining motion signals can be used to
wire multiple systems in a daisy chain configuration.

Hold Ignition

Input

When active system will stay in preflow and delay torch ignition.

System Error

Output

Indicates that an error has occurred in the plasma system