Command table (7 of 13) – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 257

Advertising
background image

APPENDIX B – CNC INTERFACE PROTOCOL

b-12

HPR260 Auto Gas

Instruction Manual

Command table (7 of 13)

ID

Command

System

Description

096 SET_INLET_GASES

Auto gas system

Set inlet gases for auto console. If inlet gases change, the
power supply will enter the purge state. Gas type changes
are not allowed when the system is cutting (state 4 – state
10).

Data:
Plasma gas type code (See table VI),
Shield gas type code (See table VI),
Space delimited.

Return value:
1= accepted, 0 = not accepted

Sample:
>0961 626< (Set plasma gas = O2 and set shield gas = N2)
>0961D0<

097 READ_CORNER_CURRENT

Manual gas system
Auto gas system

Read the corner-current percentage

Data:
None

Return value:
Percentage

Sample:
>097A0<
>09700756C< (75%)

098 GET_INLET_GASES

Manual gas system
Auto gas system

Read the inlet gas types
Data:
None

Return value:
Plasma gas type code (See table VI),
Shield gas type code (See table VI),
Space delimited

Sample:
>098A1<
>0980001 000648< (Plasma gas = O2 and shield gas = N2)

099 GET_GAS_FLOWS

Auto gas system

Read the gas setpoints
Data:
None

Return value:
Plasma cutflow setpoint (psi),
Plasma preflow setpoint (psi),
Shield cutflow setpoint (psi),
Shield preflow setpoint (psi),
N2 Mix setpoint (psi),
Gas 2 mix setpoint (psi)
Space delimited.

(55 = 55 psi)

Sample:
>099A2<
>0990055 0045 0035 0025 0050 0050EE<

5

Advertising