Mild steel, Marking, Metric – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 274: English, Plasma / air shield 200 a cutting

Advertising
background image

APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS

HPR260 Auto Gas

Instruction Manual

c-5

Plasma Shield Plasma Shield Plasma Shield

mm

Volts

mm

factor %

seconds

6

124

0.2

10

126

0.3

12

128

0.5

15

131

0.6

20

133

0.8

25

143

1.0

32

145

N/A

38

152

N/A

50

163

N/A

Plasma Shield Plasma Shield Plasma Shield

in

Volts

in

factor %

seconds

3/16

124

0.2

1/4

124

0.2

3/8

126

0.3

1/2

128

0.5

5/8

131

0.6

3/4

133

0.8

1

143

1.0

1-1/4

145

N/A

1-1/2

152

N/A

2

163

N/A

Marking

Amperage

Plasma Shield Plasma Shield Plasma Shield

Amps

mm

in

mm/min ipm

N

2

N

2

10

10

10

10

15

2.5

0.100

6350

250

Metric

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

mm

mm/m

O

2

Air

23

49

74

20

3.3

5250

6.6

200

3460

3060

4.1

2275

8.2

1575

5.1

1165

10.2

750

510

255

English

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

in

ipm

O2

Air

23

49

74

20

0.130

230

0.260

200

200

140

115

0.160

80

0.320

65

0.200

45

0.400

30

20

10

Volts

130

Select

Gases

Set

Preflow

Set

Cutflow

Torch-to-Work

Distance

Marking

Speed

Arc

Voltage

Mild steel

O

2

Plasma / Air Shield

200 A Cutting

Flow rates – lpm/scfh

O

2

Air

Preflow

0 / 0

128 / 270

Cutflow

39 / 82

48 / 101

220356

220398

220352

220355

220353

220354

Advertising