INSTALLATION

HPR260 Auto Gas

Instruction Manual

3-39

5

0

0

0

0

0

0

0

0

-7

-6

-5

-4

-3

-2

-1

10

20

30

40

0

10

20

30

40

50

60

-57

-51

-46

-40

-34

-29

-23

-18

-12

-7

-1

4

T

e

mperature

% of Propylene Glycol

Caution: For operating temperatures colder than the temperature stated above,

the percentage of propylene glycol must be increased. Failure to do so
could result in a cracked torch head, hoses or other damage to the torch
coolant system due to freezing.

Hypertherm pre-mix (028872)

Maximum glycol percentage

°F

°C

Coolant for cold operating temperatures (below 0° C / 32° F)

Use a custom coolant mix when operating in temperatures below 0° C (32° F).

Use the chart below to determine what percentage of propylene glycol to use in the mixture.

Mix 100% glycol (028873) with the premixed Hypertherm coolant (028872) to increase the percentage of glycol. The
100% glycol solution can also be mixed with purified water (see next page for water purity requirements) to achieve the
required protection from freezing.

Note: Maximum percentage of glycol should never exceed 50%.