APPENDIX B – CNC INTERFACE PROTOCOL

b-10

HPR260 Auto Gas

Instruction Manual

Command table (5 of 13)

ID

Command

System

Description

079

GET_PS_INFO

Manual gas system
Auto gas system

Returns pressures, system state, and system error, space
delimited

Data:
None

Return value:
Plasma cutflow pressure (0044 = 44 psi)
Plasma preflow pressure (0044 = 44 psi)
Shield cutflow pressure (0044 = 44 psi)
Shield preflow pressure (0044 = 44 psi)
Current setpoint (amps)
System state (see table V) (0003 = state 3)
System error (see table IV) (0000 = error 0)
Cut gas 1 pressure (0044 = 44 psi)
Cut gas 2 pressure (0044 = 44 psi)
N2 Mix inlet pressure (0044 = 44 psi)
Gas2 Mix inlet pressure (0044 = 44 psi)

Note:

Cut gas 1, Cut gas 2, N2 mix inlet, and Gas 2 mix inlet are

not measured in the manual gas console configuration.

Sample:
>079A0<
>079PC0044 PP0042 SC0034 SP0035 CS0040 ST0003
ER0000 CG0000 CG0000 MV0000 MV0000DE<

084

DOWNLOAD_SOFTWARE

Not currently implemented on the
HD4070 or the HPR systems

TBD

Download new firmware to the plasma system.

Data:
TBD

Return value:
1 = packet accepted, 0 = not accepted

Sample:
TBD

085

WAKE

Manual gas system
Auto gas system

This command is used to wake a system and enable its
transmitter to communicate on a multi drop line.

Data:
System ID, which is set by dipswitches on PC board.

Return value:
Echo of the command

Sample:
>0850CD<
>0850CD<

086

SLEEP

Manual gas system
Auto gas system

Tell all systems on the line to disconnect their transmitters

Data:
None

Return value:
None

Sample:
>0869E<

No response

5