Mild steel, Plasma / air shield 80 a cutting, Marking – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 272: Metric, English

Advertising
background image

APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS

HPR260 Auto Gas

Instruction Manual

c-3

Mild steel

O

2

Plasma / Air Shield

80 A Cutting

220189

220173

220187

220176

220179

220188

Flow rates – lpm/scfh

O

2

Air

Preflow

0 / 0

76 / 161

Cutflow

23 / 48

41 / 87

Plasma Shield Plasma Shield Plasma Shield

mm

Volts

mm

factor %

seconds

2

112

2.5

115

3

117

4

120

6

123

0.3

10

127

0.5

12

130

0.7

15

133

0.8

20

135

6.3

0.9

Plasma Shield Plasma Shield Plasma Shield

in

Volts

in

factor %

seconds

.075

112

.105

115

.135

117

3/16

120

1/4

123

0.3

3/8

127

0.5

1/2

130

0.7

5/8

133

0.8

3/4

135

0.250

0.9

Marking

Amperage

Amps

mm

in

mm/min ipm

N

2

N

2

10

10

10

10

15

2.5

0.100

6350

250

250

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

0.200

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

0.160

0.100

in

ipm

400

0.150

Pierce Delay

Time

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Initial Pierce

Height

0.2

200

110

75

250

5.0

545

3045

1810

1410

O

2

Air

48

27

15

2.5

2.0

78

23

2.5

0.2

0.1

3.8

150

200

4.0

Pierce Delay

Time

Metric

37

25

15

0.100

0.080

155

50

78

English

0.1

23

O

2

Air

48

27

150

290

180

Select

Gases

Marking

Speed

Torch-to-Work

Distance

mm

mm/m

1030

9810

7980

6145

4300

Volts

130

Set

Cutflow

Set

Preflow

Arc

Voltage

Advertising