Error code troubleshooting – 10 of 10

Error code

number

Name

Description

Corrective action

144

Internal flash

error

Manual Gas

Only

Communication problem
to the flash chip on
the gas console control
board.

1. Replace the control board.

145

Internal flash

error

Auto Gas

Only

Communication problem
to the flash chip on
the selection console
control board.

1. Replace the control board.

151

Software fail

Software has detected an
incorrect state or
condition.

1. Replace power supply control board.

152

Internal flash

error

Communication problem
to the flash chip on
the power supply control
board.

1. Replace the control board.

153

PS EEPROM

error

EEPROM memory on
power supply control
board not working.

1. Replace the control board.

180

Selection

console CAN

timeout

Auto Gas

Only

The power supply did not
receive a CAN message
from the selection console
within 1 second.

1. Verify that the power supply-to-selection console

CONTROL and POWER cables are not damaged and are
properly connected to PCB3, and the rear of the selection
console.

2. Verify that D17 (+5 VDC) and D18 (+3.3 VDC) are

illuminated on PCB2 inside the selection console. These
LEDs indicate power to PCB2. Also verify that D26 (CAN -
RX) and D27 (CAN - TX) are illuminated on PCB2 inside
the selection console. These LEDs indicate communication
between the selection console and the power supply.

3. If power is present at PCB2 and PCB3 and both selection

console cables are good, then PCB2 or PCB3 has failed.
Use the CAN tester to verify which board needs to be
replaced.

181

Metering

console CAN

timeout

Auto Gas

Only

The power supply did not
receive a CAN message
from the metering console
within 1 second.

1. Verify that the power supply-to-metering console

CONTROL and POWER cables are not damaged and are
properly connected to PCB3, and the rear of the metering
console.

2. Verify that D17 (+5 VDC) and D18 (+3.3 VDC) are

illuminated on PCB2 inside the metering console. These
LEDs indicate power to PCB2. Also verify that D26 (CAN -
RX) and D27 (CAN - TX) are illuminated on PCB2 inside
the metering console. These LEDs indicate communication
between the metering console and the power supply.

3. If power is present at PCB2 and PCB3 and both metering

console cables are good, then PCB2 or PCB3 has failed.
Use the CAN tester to verify which board needs to be
replaced.