MAINTENANCE

HPR260 Auto Gas

Instruction Manual

5-5

Sequence of operation

1. Power-up – The system verifies that all of these signals are off at power-up

Coolant flow off
Chopper current off
Transfer off
Phase-loss off
Chopper 1 overtemp off
Magnetics overtemp off
Coolant overtemp off
Plasma start off

2. Purge – Air or N

2

gas flows through torch for 20 seconds

Contactor closes and the chopper performs a chopper test and a current sensor test
Plasma start off
Contactor opens when the purge cycle ends

3. Idle

Gas pressure ok
Coolant flow on
Chopper current off
Line voltage ok

4. Preflow – 2-second flow of gas

5. Pilot arc – Current flows between electrode and nozzle

Chopper, main contactor and pilot arc relay are on
High frequency present
Chopper current sensor = pilot arc current

6. Transfer – Pilot arc current sensed on the worklead

7. Ramp-up – Chopper current increases to its setpoint and gas changes to cutflow

Coolant flow on
Gas pressure ok
Phase-loss on
Line voltage ok

8. Steady state – normal operating parameters

Coolant flow on
Gas pressure ok
Phase loss on
Chopper 1 overtemp off
Magnetics overtemp off
Coolant overtemp off

9. Ramp-down – Current and gas flow decrease after plasma start has been removed

Cutflow gas off

10. Auto Off – 10-second postflow

Main contactors off
Choppers off