Msds – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 243

Advertising
background image

9/2/04

a-4

Hypertherm

Plasma systems

SECTION 8 – EXPOSURE CONTROLS / PERSONAL PROTECTION

SECTION 9 – PHYSICAL AND CHEMICAL PROPERTIES

SECTION 10 – STABILITY AND REACTIVITY

SECTION 11 – TOXICOLOGICAL INFORMATION

Hygienic practices

Engineering controls

Normal procedures for good hygiene.

Good general ventilation. Eye wash station in immediate area of use.
M.E.L./O.E.S

Nil.

U.K HSE EH:40

Not listed

Personal protective equipment

X

Respirator

X

goggles / face shield

APRON

X

Gloves

Boots

If exposed to mists.
Recommended

Recommended; PVC, Neoprene or Nitrile acceptable

Appearance

Clear Pink/Red Liquid

Boiling point

100EC

None

freezing point

Not established

5,5-7,0

vapor pressure

Not applicable

1,0

vapor density

Not applicable

Complete

evaporation rate

Not determined

ODOR
pH of Concentrate
Specific gravity
solubility in water

Chemical Stability

None

None Known

BY FIRE: Carbon Dioxide, Carbon Monoxide Nitrogen Oxides

Will not occur

X

May occur

Not applicable

Incompatibility

Conditions to avoid

Hazardous products of
decomposition

Polymerization

Conditions to avoid

Stable

Unstable

X

Carcinogenicity

THIS PRODUCT CONTAINS A KNOWN OR SUSPECTED CARCINOGEN

X

THIS PRODUCT DOES NOT CONTAIN ANY KNOWN OR ANTICIPATED CARCINOGENS ACCORDING
TO THE CRITERIA OF THE NTP ANNUAL REPORT ON CARCINOGENS AND OSHA 29 CFR 1910, Z

Other effects

Acute

Chronic

Not determined
Not determined

MSDS

Page 3 of 4

Product

Hypertherm Torch Coolant

CODE